L2 ECMP: return traffic not sent to correct SI if multiple SIs on same compute

Bug #1648928 reported by amit surana
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Juniper Openstack
Status tracked in Trunk
R3.0
New
High
Naveen N
R3.1
Fix Committed
High
Naveen N
R3.2
Fix Committed
High
Naveen N
Trunk
Fix Committed
High
Naveen N

Bug Description

consider this topology:

client-----SI(s)------Server

Lets say SI->Server packets are bridged and server to SI packets are routed. If there are multiple instances of the SI, then the return traffic must be sent back to the SI from which the packet was received. This works correctly as long as there is only 1 SI on a compute node. Flow symmetry must also be supported for cases where multiple instances of the SI might be running on the same compute.

Tags: vrouter
Revision history for this message
Hari Prasad Killi (haripk) wrote :

Release Note: When forward flow is bridged and reverse is routed (SI in ECMP), having multiple SIs on the same compute node is not supported.

Revision history for this message
Hari Prasad Killi (haripk) wrote :

Changes committed as part of 1648696 and 1645978.