[2.3, HWTv2, UI] Aborting commissioning (+ testing) of a machine never commissioned before, leaves 'pending' icons in the UI
Bug #1731350 reported by
Andres Rodriguez
This bug affects 1 person
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
MAAS |
Fix Released
|
Medium
|
Lee Trager |
Bug Description
Aborting commissioning (with testing) with a machine that has never been commissioned before, leaves 'pending' UI icons even though status of scripts are marked as aborted.
1. Add a machine
2. Starts commissioning
2. Click on 'Abort' action
3. The machine goes back to NEW
4. UI -> machine listing shows as 'pending'
5. UI -> machine details tabs show as 'pending'
6. UI -> tests or commissioning scripts show *correctly* as 'aborted'.
Related branches
~ltrager/maas:lp1731350
- Andres Rodriguez (community): Approve
-
Diff: 68 lines (+35/-4)2 files modifiedsrc/maasserver/websockets/handlers/node.py (+15/-4)
src/maasserver/websockets/handlers/tests/test_machine.py (+20/-0)
Changed in maas: | |
milestone: | none → 2.3.0rc2 |
importance: | Undecided → Medium |
status: | New → Triaged |
Changed in maas: | |
status: | Triaged → In Progress |
Changed in maas: | |
status: | In Progress → Fix Committed |
Changed in maas: | |
status: | Fix Committed → Fix Released |
To post a comment you must log in.
Video attached.