os-collect-config does not automatically start on boot when using split stack (ocata only)

Bug #1734783 reported by Alex Schultz
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
tripleo
Fix Released
Medium
Alex Schultz

Bug Description

When using pre-provisioned nodes with Ocata, the os-collect-config service is not enabled by the get-occ-config.sh script. This was fixed in Pike with https://github.com/openstack/tripleo-heat-templates/commit/5e934cd9b8b17c62a2f8729a1e6f50b9b9001ff8 but this includes switching to use a local collector which may not work when applied to an existing environment. For ocata we should just ensure that the service is properly enabled in get-occ-config.sh.

Changed in tripleo:
assignee: nobody → Alex Schultz (alex-schultz)
Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix proposed to tripleo-heat-templates (stable/ocata)

Fix proposed to branch: stable/ocata
Review: https://review.openstack.org/523245

Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix merged to tripleo-heat-templates (stable/ocata)

Reviewed: https://review.openstack.org/523245
Committed: https://git.openstack.org/cgit/openstack/tripleo-heat-templates/commit/?id=828bc54f84c4eb06d5b0bdfb470cff7014adf58b
Submitter: Zuul
Branch: stable/ocata

commit 828bc54f84c4eb06d5b0bdfb470cff7014adf58b
Author: Alex Schultz <email address hidden>
Date: Mon Nov 27 16:13:37 2017 -0700

    Enable os-collect-config service

    When using get-occ-config.sh to configure pre-provisioned nodes, the
    os-collect-config service may not have been enabled by default. This can
    lead to reboots causing future updates or upgrade processes to fail.

    Change-Id: If7d4dbcc721fbb0ea835dbd70126f9532a94d937
    Closes-Bug: #1734783

tags: added: in-stable-ocata
Changed in tripleo:
milestone: queens-2 → queens-3
Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix included in openstack/tripleo-heat-templates 6.2.7

This issue was fixed in the openstack/tripleo-heat-templates 6.2.7 release.

Changed in tripleo:
milestone: queens-3 → queens-rc1
Changed in tripleo:
milestone: queens-rc1 → rocky-1
Changed in tripleo:
status: Triaged → Fix Released
To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches