"Shut down" option shows the Lock/Log out dialog

Bug #1676426 reported by Michał Sawicz
16
This bug affects 3 people
Affects Status Importance Assigned to Milestone
Canonical System Image
Fix Released
High
Michał Sawicz
indicator-session (Ubuntu)
Invalid
Undecided
Unassigned
unity8 (Ubuntu)
Fix Released
Undecided
Lukáš Tinkl

Bug Description

Session menu → Shut down - shows Log out / Lock dialog instead of Shut down / Restart.

ProblemType: Bug
DistroRelease: Ubuntu 17.04
Package: unity8 8.15+17.04.20170321-0ubuntu1
ProcVersionSignature: Ubuntu 4.10.0-14.16-generic 4.10.3
Uname: Linux 4.10.0-14-generic x86_64
NonfreeKernelModules: zfs zunicode zavl zcommon znvpair
ApportVersion: 2.20.4-0ubuntu2
Architecture: amd64
CurrentDesktop: Unity:Unity7
Date: Mon Mar 27 15:06:43 2017
InstallationDate: Installed on 2016-05-06 (324 days ago)
InstallationMedia: Ubuntu 16.04 LTS "Xenial Xerus" - Release amd64 (20160420.1)
SourcePackage: unity8
UpgradeStatus: Upgraded to zesty on 2016-11-22 (124 days ago)

Related branches

Revision history for this message
Michał Sawicz (saviq) wrote :
Changed in canonical-devices-system-image:
status: New → Triaged
importance: Undecided → High
milestone: none → u8c-z
assignee: nobody → Michał Sawicz (saviq)
Changed in unity8 (Ubuntu):
status: New → Incomplete
Revision history for this message
Launchpad Janitor (janitor) wrote :

Status changed to 'Confirmed' because the bug affects multiple users.

Changed in indicator-session (Ubuntu):
status: New → Confirmed
Changed in unity8 (Ubuntu):
status: Incomplete → In Progress
assignee: nobody → Lukáš Tinkl (lukas-kde)
Changed in indicator-session (Ubuntu):
status: Confirmed → Invalid
tags: added: unity8-desktop
Michał Sawicz (saviq)
Changed in canonical-devices-system-image:
status: Triaged → In Progress
Revision history for this message
Launchpad Janitor (janitor) wrote :

This bug was fixed in the package unity8 - 8.15+17.04.20170328.3-0ubuntu1

---------------
unity8 (8.15+17.04.20170328.3-0ubuntu1) zesty; urgency=medium

  [ Albert Astals Cid ]
  * mock: Remove empty property and move invokable
  * Tune quicklist item selection
  * Fix unminimizing going to the wrong position the second time (LP:
    #1671458)
  * Remove unclickable gaps on the menubar (LP: #1672722)
  * indicators client is a tool
  * Make sure we destroy the popups when the item goes away (LP:
    #1670338)
  * UnityApplicationMocks: Initialize m_state and m_requestedState
  * Don't use appInfo after checking it if is null
  * Initialize m_privateMode
  * Hook up aboutToShow for overflow menus (LP: #1676016)

  [ Daniel d'Andrada ]
  * Give active focus to child surface qml items (LP: #1671072)
  * Satellite child windows (LP: #1673415)
  * Tell qtmir/miral about the available desktop area

  [ Florian Boucault ]
  * WindowStateStorage: use a private QThreadPool to ensure that
    WindowStateStorage::saveValue always has a thread available to
    execute the query in. (LP: #1675424)

  [ Lukáš Tinkl ]
  * Protect against loading invalid window geometry (LP: #1674262)
  * Remove usage of the deprecated (and non-functional) system-image-
    dbus service.
  * Implement Ctrl+Alt+T to launch the terminal app (LP: #1673500)
  * Only take normal and dialog surface types into account for launcher
    items (LP: #1669047)
  * Fix the shutdown dialog after recent refactoring in
    DBusUnitySessionService (LP: #1676426)

  [ Michael Zanetti ]
  * drop the grey background behind icons in the drawer (LP: #1675688)

  [ Pete Woods ]
  * Fix Unity/Platform::isPC, and add tests (LP: #1670657)

 -- Michał Sawicz <email address hidden> Tue, 28 Mar 2017 21:50:20 +0000

Changed in unity8 (Ubuntu):
status: In Progress → Fix Released
Michał Sawicz (saviq)
Changed in canonical-devices-system-image:
status: In Progress → Fix Released
To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches

Bug watches keep track of this bug in other bug trackers.